The system’s user-friendly software requires minimal training and provides simple, visual results. Clinicians can set up a file for each client, store stills or videos of pressure images, then share them via email. Advanced data security keeps your client’s information safe.

The ForeSite SS system

With a combination of accuracy, calibration stability, conformability, image quality, and durability, ForeSite SS is the most advanced pressure imaging system available for wheelchair assessment.

  • Sensor is very thin, flexible, and light, so it conforms to the chair’s seat and back, providing an accurate view of pressure distribution
  • Sensor provides superior image quality while continuously measuring the body surface pressures
  • Touchscreen tablet displays real-time images of elevated pressures
  • ForeSite SS software clearly shows the various pressures applied to the sensor pad, highlighting higher or lower values in the pressure distribution

imageForeSiteWheelchair1-0006.png      

The LX100 sensor, our preferred sensor offering, features superior image quality and is cleanable, eliminating the need for disposable sleeves. It is durable, yet light and flexible for better conformability. The extremely accurate sensor never needs to be recalibrated—so you can rely on accurate pressure measurements for the entire life of the sensor.

Benefits

  • Wireless communication between sensor and tablet
  • Medically-certified system that’s light, modern, and easy to use
  • Heightened data security, including data encryption
  • An intuitive, user-friendly interface — it’s simple to learn and allows the user more control over client files
  • The ability to capture and manage still frame images and recordings
  • Generate reports within the software
  • Easily transferable data and images — data sharing and transfer between users is greatly simplified
  • Our preferred sensor offering is the extremely accurate, permanently calibrated LX100 sensor
  • WiFi Connectability allows users to send data via email

Select Model
SENSOR
Model: LX100:36.36.02
Total Area: 26 x 26 inches (66cm x 66cm)
Sensing Area: 18 x 18 inches (45.7cm x 45.7cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.07–2.7 N/cm2 (0.1–3.87psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 5% full scale
Sampling Frame Rate: 45 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: PX100:36.36.02
Total Area: 26 x 26 inches (66cm x 66cm)
Sensing Area: 18 x 18 inches (45.7cm x 45.7cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.14–2.7 N/cm2 (0.2–3.87psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 10% full scale
Sampling Frame Rate: 45 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: LX100:40.40.02
Total Area: 28 x 28 inches (71.1cm x 71.1cm)
Sensing Area: 20 x 20 inches (50.8cm x 50.8cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.07–2.7 N/cm2 (0.1–3.87psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 5% full scale
Sampling Frame Rate: 39 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: PX100:40.40.02
Total Area: 28 x 28 inches (71.1cm x 71.1cm)
Sensing Area: 20 x 20 inches (50.8cm x 50.8cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.14–2.7 N/cm2 (0.2–3.87psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 10% full scale
Sampling Frame Rate: 39 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: LX100:48.48.02
Total Area: 32 x 32 inches (81.3 cm x 81.3cm)
Sensing Area: 24 x 24 inches (60.9cm x 60.9cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.07–2.7 N/cm2 (0.2–3.87psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 5% full scale
Sampling Frame Rate: 33 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: PX100:48.48.02
Total Area: 32 x 32 inches (81.3 cm x 81.3cm)
Sensing Area: 24 x 24 inches (60.9cm x 60.9cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.14–2.7 N/cm2 (0.2–3.87psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 10% full scale
Sampling Frame Rate: 45 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: LX100:40.64.02
Total Area: 28 x 40 inches (71.1 cm x 111.7cm)
Sensing Area: 20 x 32 inches (50.8cm x 81.2cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.07–2.7 N/cm2 (0.1–3.87psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 5% full scale
Sampling Frame Rate: 39 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: PX100:40.64.02
Total Area: 28 x 40 inches (71.1 cm x 111.7cm)
Sensing Area: 20 x 32 inches (50.8cm x 81.2cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.14–2.7 N/cm2 (0.2–3.87psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 10% full scale
Sampling Frame Rate: 39 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: PX100:26.64.01
Total Area: 40.5 x 88 inches (102.8 cm x 223.5cm)
Sensing Area: 32 x 80 inches (81.2 cm x 203.2 cm)
Spatial Resolution: 1.25 inches (31.75mm)
Pressure Range: 0.07–0.69 N/cm2 (0.1–1.0 psi),
0.07–1.33 N/cm2 (0.1–2.0 psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 10% full scale
Sampling Frame Rate: 53 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: PX100:48.144.02
Total Area: 33 x 81 inches (83.8 cm x 205.7cm)
Sensing Area: 24 x 72 inches (60.9 cm x 182.9 cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.07–0.69 N/cm2 (0.1–1.0 psi),
0.07–1.33 N/cm2 (0.1–2.0 psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 10% full scale
Sampling Frame Rate: 23 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
SENSOR
Model: PX100:64.160.02
Total Area: 41 x 96 inches (104.1 cm x 243.8cm)
Sensing Area: 32 x 80 inches (81.3 cm x 203.2 cm)
Spatial Resolution: 0.5 inches (12.7mm)
Pressure Range: 0.07–0.69 N/cm2 (0.1–1.0 psi),
0.07–1.33 N/cm2 (0.1–2.0 psi)
Calibration: ISO/IEC 17025 Accredited
Accuracy: ± 10% full scale
Sampling Frame Rate: 17 frames/s
SYSTEM
Risk Management: EN ISO 14971
Electrical/Mechanical Safety: IEC/EN 60601-1
Electromagnetic Compatibility: IEC EN 60601-1-2
Biocompatibility: ISO 10993-1
FORESITE SS TABLET
Certifications: CE, FCC, EN60601-1-22
Display: 9.7 inch high quality LED Panel
Resolution: 1024x768
Touchscreen: Capacitative multi-touch
Dimensions: (WXLXH) 267 x 210.6 x 22mm
Weight: 0.99 Kg (w/o accessories)
Operating Temperature: 0 degrees C to 50 degrees C
Operating Humidity: 30% to 90% (non-condensing)
IP Proof: IP54 water and dust proof
Power Input: 12V DC
 Power Consumption: 9 W typ.

logoForeSiteCE1.png

logoForeSiteTUV1.png

logoForeSiteFC1.png

 
Complies with EN 60601-1-2 Standard for Medical Electrical Equipment and Medical Electrical Systems

bottonNav1-0001-0001.png

Request a Quote

Request a customized quote on products and services.

bottonNav4-0001.png

Download Brochure

To download a copy of our ForeSite SS brochure click here.

bottonNav3-0001.png

Contact Us

Call or email XSENSOR to talk with a knowledgeable specialist.